Designed for 13S Li-ion Battery management system
Max constant charge current 40A
Max constant discharge current 40A
Item: WS-24S60A-035(13S) | ||||
Item | Specification | |||
1 | Voltage | Charge voltage | DC:54.6V CC/CV | |
2 | Current | |||
Self discharge(Single cell) | ≤20μA | |||
Max constant charge current | 40A | |||
Max constant discharge current | 40A | |||
3 | Over charge(Single cell) | Over charge voltage | 4.25±0.025V | |
Overcharge detection delay time | 0.5S—1.5S | |||
Overcharge recovery voltage | 4.05±0.05V | |||
4 | Over Discharge(Single cell) | Overdischarge detection voltage | 2.50±0.062V | |
Over discharge detection delay time | 10mS—150mS | |||
Over-discharge recovery voltage | 2.50±0.062V | |||
5 | Over current | Over discharge current detection voltage | 0.62V | |
Over discharge current detection current | 180±30A | |||
Overcurrent detection delay time | 5ms—15ms | |||
Recovery status | Disconnect the load, automatic recovery | |||
6 | Short Circuit | Detection Status | External short circuit | |
Detection delay time | 200-500us | |||
Recovery status | Disconnect the load, automatic recovery | |||
7 | internal resistance | Protection(MOSFET) | ≤20mΩ | |
8 | Temperature | Operating temperature range | -40~+85℃ | |
Storage temperature range | -40~+125℃ |